Isolation Transformer
Description
Technical Parameters
Product introduction
Isolation transformer
Our three-phase dry-type isolation transformers are a new generation of energy-saving power transformers, developed based on references to similar international products and tailored to China's specific conditions. Available in capacities from 300VA to 1600kVA, they comply with international and national standards such as IEC439 and GB5226. The windings utilize a full-row winding method, and the transformers are vacuum-impregnated with varnish, achieving insulation grades of F or H. The product's performance reaches advanced domestic and international standards. The QSG/SG series three-phase dry-type isolation transformers are widely used in AC circuits operating at 50Hz to 60Hz and voltages up to 2000V.
It is widely used in imported important equipment, precision machine tools, electromechanical equipment, medical equipment, rectification, lighting, etc. The various input and output voltages, connection groups, number and position of adjustment taps (generally ±5%), distribution of winding capacity, configuration of secondary single-phase winding, working mode of rectification circuit, whether or not a shell is required, etc. of the product can be carefully designed and manufactured according to user requirements.
Product Details
A,Single-phase isolation transformer:
Input Voltage: 220V/380V
Typical Applications: Small medical devices, laboratory instruments, precision electronics
Features: Compact size and flexible installation, suitable for space-constrained locations.
B,Three-phase isolation transformer:
Input voltage: 380V
Typical applications: Industrial production lines, large medical equipment, and data centers.
Features: High output power, excellent stability, and support for delta-y conversion.
Structural characteristics
1. Electrical Isolation: Establishes a novel neutral-point grounding system to eliminate common-mode interference.
2. Voltage Conversion: Supports ΔΔ-YO or YO-ΔΔ connection conversion.
3. Shielding: Optional shielding layer (must be strictly grounded) suppresses high-frequency interference.
working conditions
- Altitude not exceeding 2500m
- Ambient medium temperature: not less than -25°C, not more than +40°C;
- Current and voltage waveforms are approximately sinusoidal;
- Location protected from rain and snow, and free from significant shaking, shock, or vibration;
- In a non-explosive medium free of gases and conductive dust that could corrode metals or damage insulation;
- Input and output voltages can be customized according to customer needs
Main specifications
|
Rated capacity KVA |
Voltage combination and tapping range |
Connection group symbols |
No-load loss |
Load loss (W) |
No-load current(%) |
Short-circuit impedance(%) |
||
|
high pressure |
Faucet range |
low pressure KV |
||||||
|
三十 |
1110.510 |
±5±2×2.5% |
0.4 |
YynODyn11 |
190 |
710 |
2.1 |
4 |
|
50 |
270 |
1000 |
2.1 |
4 |
||||
|
80 |
370 |
1380 |
1.6 |
4 |
||||
|
100 |
400 |
1570 |
1.6 |
4 |
||||
|
125 |
470 |
1850 |
1.5 |
4 |
||||
|
160 |
540 |
2130 |
1.5 |
4 |
||||
|
200 |
620 |
2530 |
1.3 |
4 |
||||
|
250 |
720 |
2760 |
1.3 |
4 |
||||
|
315 |
880 |
3470 |
1.1 |
4 |
||||
|
400 |
980 |
3990 |
1.1 |
4 |
||||
|
500 |
1160 |
4880 |
1.1 |
4 |
||||
|
630 |
1340 |
5880 |
0.9 |
4 |
||||
|
630 |
1300 |
5960 |
0.9 |
6 |
||||
|
800 |
1520 |
5960 |
0.9 |
6 |
||||
|
1000 |
1770 |
8130 |
0.9 |
6 |
||||
|
1250 |
2090 |
9690 |
0.9 |
6 |
||||
|
1600 |
2450 |
11730 |
0.9 |
6 |
||||
|
2000 |
3050 |
14450 |
0.9 |
6 |
||||
Quality Control and Certification
Before leaving the factory, each transformer must pass a series of rigorous tests using advanced equipment, covering multiple measurement indicators.
|
Test items |
|||
|
No. |
Test Name |
Routine testing |
Optional Test |
|
1 |
Input voltage test |
√ |
|
|
2 |
0 output voltage test |
√ |
|
|
3 |
No-load loss and current test |
√ |
|
|
4 |
PRI leak perception test |
√ |
|
|
5 |
Insulation resistance |
√ |
|
|
6 |
Impedance voltage |
√ |
|
|
7 |
Stress testing |
√ |
|
|
8 |
Insulation resistance |
√ |
|
|
9 |
Winding resistance test |
√ |
|
|
10 |
Temperature rise test |
√ |
√ |
|
11 |
efficiency |
√ |
|
|
12 |
Connection method |
√ |
|
|
13 |
Surge current test |
√ |
|
|
14 |
Noise level test |
√ |
|
|
15 |
Waterproof test |
√ |
|
FAQ
Q: What material is used for the transformer?
A: We offer two types, depending on your requirements. One is 100% copper, and the other is copper-aluminum. Please note that the cost of each type varies.
Q: What is the output accuracy?
A: Typically, the factory setting is ±2%, but customization is possible from ±0.5% to ±5%.
Q: What does the input voltage range/window of a voltage regulator mean?
A: For example, a voltage regulator with an input voltage range/window of ±20% and a rated voltage of 400V can continuously provide a 400V output when the input voltage is within the range of 400V ±20% (320V to 480V). If the input voltage is below 320V, the output voltage will be below 400V; if the input voltage exceeds 480V, the output voltage will also exceed 400V. This is a very important parameter that users should consider.
Q: If a quality problem occurs, how should it be resolved?
A: Follow the analysis steps to identify the key cause of the problem. We usually provide spare parts free of charge during the warranty period.
Q: How should I perform regular preventive maintenance?
A: The AVR must be cleaned of dust and carbon dust every 6 to 12 months of operation. Pay attention to the brush surfaces and the autotransformer surfaces where the brushes contact. Clean with a soft brush or dry cloth.
In addition, gears and drive components must be lubricated regularly with a small amount of lubricant. Check mechanical fasteners and tighten any loose screws. The three brush sets should be level.
Visit our isolation transformer production workshop


Conclusion:
As a transformer manufacturer with many years of experience, we understand that our customers choose more than just a piece of equipment; they choose a long-term partner who is crucial to the stable operation of the entire system. For decades, we have consistently focused on superior manufacturing technology, fully automated production lines, and strict quality control to ensure that every transformer we produce has exceptional performance and an exceptionally long service life. Through personalized design and full-lifecycle technical services, we are committed to creating long-term value that exceeds your expectations.
Hot Tags: isolation transformer, China isolation transformer manufacturers, suppliers, factory, 1 phase auto transformer, deck lighting transformer, electronic variac, isolation transformer, mini variac, Three phase dry type mining transformer