First of all, let's have a preliminary understanding of the inverter and soft starterFirst of all, let's have a preliminary understanding of the inverter and soft starter:
1·Soft start is step-down start, so that the starting current of the motor in the starting process is uncontrollable from the past overload impulse current to controllable. And the size of the starting current can be adjusted as needed. There is no impact torque in the whole process of motor starting, but smooth start-up operation. That's the soft start.Soft start is step-down start, so that the starting current of the motor in the starting process is uncontrollable from the past overload impulse current to controllable. And the size of the starting current can be adjusted as needed. There is no impact torque in the whole process of motor starting, but smooth start-up operation. That's the soft start.
2·The voltage varies according to different requirements, and different functions can be realized. Soft starters and frequency converters are two completely different products. The inverter is used where speed regulation is required, and its output not only changes the voltage but also changes the frequency at the same time; A soft starter is actually a voltage regulator that is used when the motor is started, and the output only changes the voltage and does not change the frequency.The voltage varies according to different requirements, and different functions can be realized. Soft starters and frequency converters are two completely different products. The inverter is used where speed regulation is required, and its output not only changes the voltage but also changes the frequency at the same time; A soft starter is actually a voltage regulator that is used when the motor is started, and the output only changes the voltage and does not change the frequency..
3·The inverter has all the features of a soft starter, but it is much more expensive and structurally complex than a soft starter. The soft starter of the motor is a soft starter connected in series between the power supply and the controlled motor to control the conduction angle of the thyristor inside it, so that the input voltage of the motor gradually rises from zero to the preset function relationship until the end of the start, giving the motor a full voltage, that is, soft starting, in the process of soft starting, the starting torque of the motor gradually increases, and the speed also gradually increases.The inverter has all the features of a soft starter, but it is much more expensive and structurally complex than a soft starter. The soft starter of the motor is a soft starter connected in series between the power supply and the controlled motor to control the conduction angle of the thyristor inside it, so that the input voltage of the motor gradually rises from zero to the preset function relationship until the end of the start, giving the motor a full voltage, that is, soft starting, in the process of soft starting, the starting torque of the motor gradually increases, and the speed also gradually increases.
4·Soft starter is a novel motor control device that integrates motor soft start, soft stop, light load energy saving and a variety of protection functions. Its main composition is a three-opposite parallel thyristor and its electronic control circuit connected in series between the power supply and the controlled motor. Different methods are used to control the conduction angle of the three opposite parallel thyristors to make the input of the controlled motor.Soft starter is a novel motor control device that integrates motor soft start, soft stop, light load energy saving and a variety of protection functions. Its main composition is a three-opposite parallel thyristor and its electronic control circuit connected in series between the power supply and the controlled motor. Different methods are used to control the conduction angle of the three opposite parallel thyristors to make the input of the controlled motor.
What is the difference between soft start and inverter?
1·Soft starter is a novel motor control device that integrates soft stop, light load energy saving and a variety of protection functions. Its main composition is a three-opposite parallel thyristor and its electronic control circuit connected in series between the power supply and the controlled motor. Different methods are used to control the conduction angle of the three opposite parallel thyristors, so that the input voltage of the controlled motor changes according to different requirements, and different functions can be realized.
2·Soft starters and frequency converters are two completely different products. The inverter is used where speed regulation is required, and its output not only changes the voltage but also changes the frequency at the same time; A soft starter is actually a voltage regulator that is used when the motor is started, and the output only changes the voltage and does not change the frequency. The inverter has all the features of a soft starter, but it is much more expensive and structurally complex than a soft starter.
Soft starters and frequency converters are two completely different products. The inverter is used where speed regulation is required, and its output not only changes the voltage but also changes the frequency at the same time; A soft starter is actually a voltage regulator that is used when the motor is started, and the output only changes the voltage and does not change the frequency. The inverter has all the features of a soft starter, but it is much more expensive and structurally complex than a soft starter.